Feb 16, 2019 DOWNLOAD: Control m user guide for z/os proclib concatenation READ ONLINE: Control m user guide for z/os proclib concatenation 16 Feb 2019 This edition applies to Version 2 Release 3 of z/OS (5650-ZOS) and to all US Government Users Restricted Rights – Use, duplication. . CONTROL-M/Desktop User Guide describes the components used. 1-2 CONTROL-M Option for Oracle Applications Administrator Guide Overview. Applications production processing (for example, OS/390 jobs, Unix shell scripts) into a single, homogenous production environment. Jul 21, 2017 MainView Batch Optimizer Job Optimizer Reference Manual IOA and INCONTROL user. This section discusses batch jobs processing and parallel steps processing for Control-M Event Manager (CMEM. Db2, FICON, Hiperspace, IBM, IMS, MVS, NetView, OS/390, Parallel Sysplex, RACF, RMF, System z, Systems Application Architecture, Tivoli, VTAM, z/OS. You have to select Control-M (Data center) and Table from the dropdown list to display all the jobs in that table. OS/390 Reactivate post-processing for the selected job. Rerun the job. Restart OS/390 Restart the job using CONTROL-R. Control M tutorial part-2. Control M Tutorial. Autosys Commands.
This appendix describes messages from external sources that are intercepted by the SMC.
IBM Operating System Messages
The messages listed in Table A-1 are received by the SMC. IBM message manuals describe the exact format (for example, spacing) and definition for each message. Ellipses indicate that the message contains more text than is shown.
Correct operation of the SMC depends on these messages. Do not suppress or alter them using products designed to handle messages through the subsystem interface (SSI). Many automated operations systems use the subsystem interface to intercept and alter or suppress messages.
Note:
If the 'suppressed by subsystem' and 'hardcopy only' bits are turned on in the WQE (the MVS write queue element) before the SMC has received the message, the SMC ignores the WTO, and the message is not displayed at the console.If you plan to use an automated operations system and are unsure about how it intercepts messages, contact the product vendor.
Although these messages may be suppressed (that is, prevented from displaying in the console) by using MPFLSTxx
parameters or an MPF
exit, the text of these messages should not be changed. The use of other WTO exits to change the display characteristics or the text of these messages is not supported by the SMC.
Volume serial numbers ('ser') as specified in messages from the operating system, are defined as follows:
Messages that contain VOLSERs with more than six characters or any character except AZ, 09, # (crosshatch), $, ¥ (yen character), and optional trailing blanks are ignored by the SMC.
Table A-1 Intercepted Operating System Messages
Control-m User Manual For Os 390 Mac
Message ID | Description |
---|---|
IEC068A | U dddd,ser |
IEC101A | M dddd,ser,... |
IEC111E | D dddd,ser |
IEC114E | D dddd... |
IEC135A | U dddd,ser... |
IEC400A | M dddd, ser... |
IEC401A | F dddd,ser... |
IEC501A | M dddd,ser{,labtyp} |
IEC501E | M dddd,ser{,labtyp} |
IEC502E | n,dddd,ser... |
IEC509A | F dddd,ser... |
IEC512I | I/O ERR|LBL ERR|SEC VOL... |
IEC701D | M dddd, VOLUME TO BE LABELED ser |
IEC702I | dddd, VOLUME LABELS CANNOT BE VERIFIED |
IEC703I | dddd, VOLUME IS FILE PROTECTED |
IEF233A | M dddd,ser{,labtyp} |
IEF233D | M dddd,ser{,labtyp} |
IEF234E | {K|D|R} dddd{,ser...} |
IGF500I | SWAP dddd to eeee - OPERATOR|I/O ERROR |
IGF502E | PROCEED WITH SWAP OF dddd TO eeee |
IGF503I | ERROR ON dddd, SELECT NEW DEVICE |
IGF509I | SWAP ddd - OPERATOR|I/O ERROR |
IGF511A | WRONG VOLUME MOUNTED ON dddd, MOUNT ser,... |
IOS000I | MVS I/O error message processed only for specific Fault Symptom Codes generated by StorageTek tape devices |
TA0233D | Message for ASM2 |
JES3 Messages
The following JES3 messages are processed by the SMC:
IAT5210
IAT5310
IAT5410
IBM message manuals describe the exact format (for example, spacing) and definition of each message.
Tape Management System Messages
SMC processes messages from several tape management systems, including CA-1, CONTROL-M/Tape, and DFSMSrmm.
CA1 Messages
The following CA1 (TMS) messages are intercepted by the SMC. Refer to the Computer Associates publication CA-1 User Manual, Volume 1 for the exact format and meaning of each message.
CTS001
CTS002
CTS004
CTS005
CTS007
CTS008
CTS009
CTS010
CTS011
CTS014
CTS015
CTT100A
CTT101A
CTT102A
CTT103A
CTT104A
CTT105A
TMS001
TMS002
TMS004
TMS005
TMS007
TMS008
TMS009
TMS010
TMS011
TMS014
TMS015
IECTMS7
CA$F810A
CA$F813A
CONTROL-M/TAPE (formerly CONTROL-T) Messages
The following CONTROL-M/TAPE messages are intercepted by the SMC. Refer to BMC's INCONTROL for OS/390 and z/OS Message Manual for the exact format and meaning of each message.
Control-m User Manual For Os 390 Free
CTT100A
CTT101A
CTT102A
CTT103A
CTT104A
CTT105A
DFSMSrmm Messages
DFSMSrmm mount message (EDG6627A
) must be acted on by the SMC when the volume or drive specified in the message is under the control of the SMC. The action of the SMC is similar to the SMC actions for the normal MVS mount messages (for example, IEC233A
, etc).
The DFSMSrmm Tape Initialization program (EDGINERS) issues a series of messages describing the success or failure of tape initialization, erasure, and verification. These messages drives the dismount of the tapes mounted from the EDG6627A
message. The following messages must be acted on by the SMC to dismount a tape:
Table A-2 Tape Management System Messages - DFSMSrmm
Message ID | Description |
---|---|
EDG6620I | VOLUME volser INITIALIZATION AND VERIFICATION SUCCESSFUL |
EDG6621E | VOLUME volser INITIALIZATION FAILED |
EDG6623I | VOLUME volser ERASE, INITIALIZATION AND VERIFICATION SUCCESSFUL |
EDG6624I | VOLUME volser ERASE FAILED |
EDG6627E | M dev VOLUME (volser) RACK (rack-number) TO BE action, lbltype |
EDG6642E | VOLUME volser LABELLED SUCCESSFULLY |
EDG6643E | VOLUME volser ERASED AND LABELLED SUCCESSFULLY |