Control-m User Manual For Os 390

Feb 16, 2019  DOWNLOAD: Control m user guide for z/os proclib concatenation READ ONLINE: Control m user guide for z/os proclib concatenation 16 Feb 2019 This edition applies to Version 2 Release 3 of z/OS (5650-ZOS) and to all US Government Users Restricted Rights – Use, duplication. . CONTROL-M/Desktop User Guide describes the components used. 1-2 CONTROL-M Option for Oracle Applications Administrator Guide Overview. Applications production processing (for example, OS/390 jobs, Unix shell scripts) into a single, homogenous production environment. Jul 21, 2017  MainView Batch Optimizer Job Optimizer Reference Manual IOA and INCONTROL user. This section discusses batch jobs processing and parallel steps processing for Control-M Event Manager (CMEM. Db2, FICON, Hiperspace, IBM, IMS, MVS, NetView, OS/390, Parallel Sysplex, RACF, RMF, System z, Systems Application Architecture, Tivoli, VTAM, z/OS. You have to select Control-M (Data center) and Table from the dropdown list to display all the jobs in that table. OS/390 Reactivate post-processing for the selected job. Rerun the job. Restart OS/390 Restart the job using CONTROL-R. Control M tutorial part-2. Control M Tutorial. Autosys Commands.

This appendix describes messages from external sources that are intercepted by the SMC.

IBM Operating System Messages

The messages listed in Table A-1 are received by the SMC. IBM message manuals describe the exact format (for example, spacing) and definition for each message. Ellipses indicate that the message contains more text than is shown.

Correct operation of the SMC depends on these messages. Do not suppress or alter them using products designed to handle messages through the subsystem interface (SSI). Many automated operations systems use the subsystem interface to intercept and alter or suppress messages.

Note:

If the 'suppressed by subsystem' and 'hardcopy only' bits are turned on in the WQE (the MVS write queue element) before the SMC has received the message, the SMC ignores the WTO, and the message is not displayed at the console.

If you plan to use an automated operations system and are unsure about how it intercepts messages, contact the product vendor.

Although these messages may be suppressed (that is, prevented from displaying in the console) by using MPFLSTxx parameters or an MPF exit, the text of these messages should not be changed. The use of other WTO exits to change the display characteristics or the text of these messages is not supported by the SMC.

Manual

Volume serial numbers ('ser') as specified in messages from the operating system, are defined as follows:

Messages that contain VOLSERs with more than six characters or any character except A­Z, 0­9, # (crosshatch), $, ¥ (yen character), and optional trailing blanks are ignored by the SMC.

Table A-1 Intercepted Operating System Messages

Control-m User Manual For Os 390 Mac

Message IDDescription

IEC068A

U dddd,ser

IEC101A

M dddd,ser,...

IEC111E

D dddd,ser

IEC114E

D dddd...

IEC135A

U dddd,ser...

IEC400A

M dddd, ser...

IEC401A

F dddd,ser...

IEC501A

M dddd,ser{,labtyp}

IEC501E

M dddd,ser{,labtyp}

IEC502E

n,dddd,ser...

IEC509A

F dddd,ser...

IEC512I

I/O ERR|LBL ERR|SEC VOL...

IEC701D

M dddd, VOLUME TO BE LABELED ser

IEC702I

dddd, VOLUME LABELS CANNOT BE VERIFIED

IEC703I

dddd, VOLUME IS FILE PROTECTED

IEF233A

M dddd,ser{,labtyp}

IEF233D

M dddd,ser{,labtyp}

IEF234E

{K|D|R} dddd{,ser...}

IGF500I

SWAP dddd to eeee - OPERATOR|I/O ERROR

IGF502E

PROCEED WITH SWAP OF dddd TO eeee

IGF503I

ERROR ON dddd, SELECT NEW DEVICE

IGF509I

SWAP ddd - OPERATOR|I/O ERROR

IGF511A

WRONG VOLUME MOUNTED ON dddd, MOUNT ser,...

IOS000I

MVS I/O error message processed only for specific Fault Symptom Codes generated by StorageTek tape devices

TA0233D

Message for ASM2


JES3 Messages

The following JES3 messages are processed by the SMC:

  • IAT5210

  • IAT5310

  • IAT5410

IBM message manuals describe the exact format (for example, spacing) and definition of each message.

Tape Management System Messages

SMC processes messages from several tape management systems, including CA-1, CONTROL-M/Tape, and DFSMSrmm.

CA­1 Messages

The following CA­1 (TMS) messages are intercepted by the SMC. Refer to the Computer Associates publication CA-1 User Manual, Volume 1 for the exact format and meaning of each message.

  • CTS001

  • CTS002

  • CTS004

  • CTS005

  • CTS007

  • CTS008

  • CTS009

  • CTS010

  • CTS011

  • CTS014

  • CTS015

  • CTT100A

  • CTT101A

  • CTT102A

  • CTT103A

  • CTT104A

  • CTT105A

  • TMS001

  • TMS002

  • TMS004

  • TMS005

  • TMS007

  • TMS008

  • TMS009

  • TMS010

  • TMS011

  • TMS014

  • TMS015

  • IECTMS7

  • CA$F810A

  • CA$F813A

CONTROL-M/TAPE (formerly CONTROL-T) Messages

The following CONTROL-M/TAPE messages are intercepted by the SMC. Refer to BMC's INCONTROL for OS/390 and z/OS Message Manual for the exact format and meaning of each message.

Control-m User Manual For Os 390 Free

  • CTT100A

  • CTT101A

  • CTT102A

  • CTT103A

  • CTT104A

  • CTT105A

DFSMSrmm Messages

DFSMSrmm mount message (EDG6627A) must be acted on by the SMC when the volume or drive specified in the message is under the control of the SMC. The action of the SMC is similar to the SMC actions for the normal MVS mount messages (for example, IEC233A, etc).

The DFSMSrmm Tape Initialization program (EDGINERS) issues a series of messages describing the success or failure of tape initialization, erasure, and verification. These messages drives the dismount of the tapes mounted from the EDG6627A message. The following messages must be acted on by the SMC to dismount a tape:

Table A-2 Tape Management System Messages - DFSMSrmm

Message IDDescription

EDG6620I

VOLUME volser INITIALIZATION AND VERIFICATION SUCCESSFUL

EDG6621E

VOLUME volser INITIALIZATION FAILED

EDG6623I

VOLUME volser ERASE, INITIALIZATION AND VERIFICATION SUCCESSFUL

EDG6624I

VOLUME volser ERASE FAILED

EDG6627E

M dev VOLUME (volser) RACK (rack-number) TO BE action, lbltype

EDG6642E

VOLUME volser LABELLED SUCCESSFULLY

EDG6643E

VOLUME volser ERASED AND LABELLED SUCCESSFULLY